1 2 3 4

Faeces pumps (PFA)

pompa PFAPFA pumps are submersible one-stack vortex pumps with a centrifugal rotor open on one side. These pumps are designated for pumping water, contaminated liquids, faeces, liquid manure and other liquids of density not exceeding 1100 kg/m3, viscosity 13 mm2/s and a length of fibrous sediments does not exceed 20 mm. Pumped liquids can have aggressiveness within corrosive resistance of the unit construction materials.

PFA pumps are used for:
• sewage treatment pumps as auxiliary units
• gardening
• farms
• emptying household septic tanks
• managing rainwater
• water removal from flooded constructions
• emptying swimming pools or tanks.

Parameters:
• modern construction solutions
• guaranteed many years of reliable work and easy access to spare parts
• continual technical supervision, and guarantee and post-guarantee technical servicing
• low purchase and operation costs
• execution of individual requirements and product customisation to customer requirements
• relatively long life cycle in difficult operating conditions.

Design
PFA unit is an one-stack vortex pump with a centrifugal rotor open on one side, driven by an induction motor through a shaft. The shaft is provided with sliding bearings in a bearing sleeve installed in the pump body. The shaft is covered by a protective-distancing sleeve, connecting the pump body with a motor connecting body. The pump body is covered with the inlet cover forming a base, on which the pump can be placed on the tank bottom. A handle with a hanger is installed on the motor tank flange, used for installing the unit in the tank opening and protecting the motor against mechanical damage during unit storage and transport.

Technical parameters

capacity

up to 39 m3/h

head

up to 9,2 m

submersion depth

up to 1,3 m

pumped liquid temperature

up to 40 oC

pumped liquid density

up to 1100 kg/m3

weight

26,2 kg

motor power

0,55 ÷ 1,5 kW

rotation speed

1420 rpm

 

Technical data divided into individual types

Pump type

PFA.2

PFA.3

PFA.4

PFA.5

capacity

- nominal

- working range

m3/h

 
10
3 ÷ 21

 
16
6 ÷ 27

 
22
9 ÷ 33

 
25
12 ÷ 39

head
- nominal
- working range

m

 
4,6
5,9 ÷ 1,4

 
4,9
6,7 ÷ 1,8

 
5,4
8,0 ÷ 2,0

 
6,5
9,2 ÷ 1,9

motor power

kW

0,55

0,75

1,10

1,50

rotation speed

min-1

1450

1450

1450

1450

voltage supply

V

400

230

400

230

400

230

400

230

M611 overload switch working range

A

1,0÷
1,6

2,5÷
4,0

1,6÷
2,5

4,0÷
6,3

2,5÷
4,0

6,3÷
10,0

4,0÷
6,3

10,0÷
16,0

M611 switch surplus

A

In (nominal motor current)

fuse current rating

A

3x10

1x25

3x16

1x25

3x25

1x50

3x25

1x50

max contamination diameter

mm

15

18

20

22

rotor diameter

mm

140

150

160

170

discharge duct diameter

mm

50

50

50

50

unit weight

kg

39

42

41

44

46

50

50

53

 

Materials used in PFA pumps

PFA pumps are produced of one set of materials

Pump parts

Material d=1

Pump bodies

grey cast iron

Rotor

grey cast iron

Closing cover

grey cast iron

Motor connecting body

grey cast iron

Driving shaft

stainless steel

Sliding bearing

e = 1 steel / rubber

e = 2 steel / bronze

Protective and distancing pipe

R35 steel

Hanger

carbon steel

Z50 hose

rubber

AP clip

galvanised carbon steel

Smooth connector

carbon steel

Fire hose type push-in fitting

h = 7 brass

h = 8 aluminium

 

PFA pump operating field

pompa pfa chka eng

Technical drawing

pompa pfa rys

Pump cross-section

pompa pfa przekroj eng

1 - Pump body

2 - Rotor

3 - Closing cover

4 - Motor connecting body

5 - Driving shaft

6 - Sliding bearing

7 - Protective-distancing sleeve

8 - Hanger

9 - Z50 hose

10 - AP clip

11 - Smooth connector

12 - Fire hose type push-in fitting